Fixing my Nixie clock with an oscilloscope and a cracked solder joint

I "built" this 6-tube Nixie clock from a pre-assembled board I got from Amazon, IN14 tubes I ordered from Russia, and soldered it together myself. It ran fine for about a month. Then all six tubes went dark at the same time, but the little purple LEDs under them stayed on.

I spent an evening working through it with Claude, and it turned into a good lesson in tracking down a problem one step at a time.

Why all six at once

Nixie tubes need about 170 volts to glow. The clock runs on 5 volts from USB, so a small circuit in one corner of the board boosts the 5 volts up to 170. Every tube shares that one circuit. One bad tube would not kill the other five, so the boost circuit was the first suspect.

The high-voltage corner of the board

That corner is the top of this photo. The small chip marked "40210" (U2) is the brains. It turns the switch next to it (Q1) on and off about 186,000 times a second. That pumps energy through the copper coil (U1) and a one-way diode (D1) into the tan capacitor (C1), which holds the high voltage for the tubes.

Narrowing it down with a meter

With the multimeter I checked the capacitor where the 170 volts should be. It read basically zero. Then I followed the 5 volts along its path. It reached the coil fine, but nothing came out the other side of it. So the power was getting in, but the circuit was not switching.

Next I checked the chip itself. It had power, and it was turned on. So why wasn't it doing anything?

First time using an oscilloscope

A meter only shows an average. To see something flipping on and off 186,000 times a second you need an oscilloscope. I have a Hantek, but I had never really used it.

The first step was to hook the probe to the test signal built into the scope. My first reading was ten times too high. The scope was set to 10X, but the switch on the probe itself was still on 1X. After I fixed that I got a proper square wave. The spikes on the corners mean the probe still needs a small adjustment, but it was good enough for this.

The scope's test signal

Then I probed pin 1 of the chip, which sets its timing. This sawtooth at about 186 kHz meant the chip was alive and running.

The chip's timing signal

The moment it clicked

The culprit:

Photo on 9 30 26 at 4.49 PM

Pin 8 is the one that sends the on/off signal to the switch. When I touched the probe tip to pin 8, the tubes lit up.

The probe itself did not fix anything. The small push from the tip pressed a cracked solder joint back together for a moment. When I looked closer, the joints on that side of the chip looked thin compared to the other side. It was probably a weak joint from when I assembled it, and a month of warming up and cooling down cracked it.

So the tip I will keep: if a problem goes away when you press on something, it is a loose connection, not a broken part.

The fix

  1. Unplug the clock and drain the capacitor. It can still hold a charge after you unplug it. A resistor across it for a few seconds does it, then check with the meter.
  2. Put some paste flux on the chip's pins.
  3. Touch each of the 10 pins with a fine soldering tip for a second or two so the solder melts and flows again.

I plugged it back in and the tubes came on and stayed on.

Working again

I still need to clean the leftover flux off with some isopropyl alcohol. At 170 volts, that residue can cause problems. I also want to go over the rest of the joints in that corner and a couple of the tube pins that looked lumpy.

Drafted with an assistant, edited by @wintaru